The SH201-C6 is a 1-pole 6A Type C miniature circuit breaker with 6kA breaking capacity from the ABB SH200 Compact Home series. Combining a delayed thermal tripping mechanism for overload protection with an electromechanical mechanism for short-circuit protection, it is a current-limiting choice for low-current lighting and control circuits in UAE residential and commercial distribution boards.
Key Features
- 1-pole 6A Type C MCB suited to low-current lighting and control circuit protection
- 6kA breaking capacity at 230/400V AC for standard UAE residential and commercial fault levels
- Dual tripping mechanism — delayed thermal for overload, electromechanical for short-circuit protection
- Current-limiting design complying with IEC/EN 60898-1 for residential applications
- Genuine ABB SH200 series quality — consistent performance and reliability
Technical Specifications
| Specification |
Details |
| Brand |
ABB |
| Model |
SH201-C6 |
| Rated Current |
6A |
| Poles |
1 |
| Tripping Characteristic |
Type C |
| Breaking Capacity |
6kA |
| Voltage |
230V AC |
| Mounting |
DIN Rail |
Applications
- Low-current lighting circuit protection in residential and commercial distribution boards
- Control and signaling circuit protection in panel builds across the UAE
- Small appliance and low-load circuit protection in consumer units
- Distribution board MCB replacement for lighting sub-circuits
FAQ
-
What's the difference between an MCB and an RCCB/RCD?
An MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.
-
What does the Type C tripping curve mean?
Type C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast/LED-driver inrush without nuisance tripping.
-
What does the 6kA breaking capacity mean?
6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.
-
How many poles do I need?
A 1-pole (1P) breaker switches the line conductor only — the standard choice for individual single-phase final circuits (lighting, sockets).
-
Is this MCB compatible with other ABB DIN-rail distribution boards?
Yes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.
-
Can I install this myself?
No. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.