ABB S202-C6 2-Pole 6A 6kA Type C MCB
The ABB S202-C6 is a 2-pole, 6A Type C miniature circuit breaker with 6kA breaking capacity from the ABB System pro M compact S200 series. Combining a delayed thermal tripping mechanism for overload protection with an electromechanical mechanism for short circuit protection, it is current limiting and suited to protecting low-current control and lighting circuits across residential, commercial and industrial UAE installations.
Key Features
- 2-pole 6A Type C MCB for low-current circuit protection in distribution boards
- 6kA breaking capacity matching standard UAE residential and commercial fault levels
- Type C tripping characteristic suitable for resistive and lightly inductive loads
- Bottom-fitting auxiliary contact compatibility, saving up to 50% panel space compared to side-mounted accessories
- Genuine ABB S200 series quality — consistent performance and reliability
Technical Specifications
| Specification |
Details |
| Brand |
ABB |
| Model |
S202-C6 |
| Rated Current |
6A |
| Poles |
2 |
| Tripping Characteristic |
Type C |
| Rated Short-Circuit Capacity |
6kA (AC/DC) |
| Rated Ultimate Breaking Capacity (Icu) |
20kA (230V) / 10kA (400V) |
| Rated Operational Voltage |
400V AC (IEC 60898-1) / 440V AC (IEC 60947-2) |
| Rated Insulation Voltage (Ui) |
440V |
| Mounting |
DIN Rail (TH35-15 / TH35-7.5) |
| Degree of Protection |
IP20 (IP40 with enclosure/cover) |
| Operating Temperature |
-25°C to +55°C |
| Mechanical Endurance |
20,000 cycles |
| Net Weight |
0.224 kg |
Applications
- Low-current lighting and control circuit protection in commercial distribution boards
- Small appliance and single-phase equipment circuit protection in UAE installations
- Control panel circuit protection for automation and BMS systems
- Distribution board circuit protection where a low-rated 2-pole breaker is required
FAQ
-
What's the difference between an MCB and an RCCB/RCD?
An MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.
-
What does the 10kA breaking capacity mean?
10kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.
-
How many poles do I need?
A 2-pole (2P) breaker switches both live and neutral together, giving full isolation on a single-phase circuit.
-
Is this MCB compatible with other ABB DIN-rail distribution boards?
Yes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.
-
Can I install this myself?
No. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.