ABB OT1000E03P 3-Pole 1000A Switch-Disconnector
The ABB OT1000E03P is a 3-pole, front-operated switch-disconnector rated for 1000A, designed for base mounting in low voltage distribution boards and panels. Fitted with a black IP65-rated handle and shaft, and supplied with a terminal bolt kit, it is built for reliable isolation duty in demanding industrial and commercial installations across the UAE.
Key Features
- 3-pole switch-disconnector rated for 1000A operational current (AC-23A) across 380–690V applications
- Black IP65-rated handle and shaft for reliable sealed manual operation, with terminal bolt kit included for straightforward installation
- High rated insulation voltage of 1000V and rated impulse withstand voltage of 12kV for robust dielectric performance
- Rated short-time withstand current (Icw) of 50kA for 1s, suitable for high fault-level panel applications
- Genuine ABB quality — manufactured to IEC 60947-3 standard
Technical Specifications
| Specification |
Details |
| Brand |
ABB |
| Model |
OT1000E03P |
| Poles |
3P |
| Rated Operational Current (AC-23A) |
1000A |
| Rated Insulation Voltage (Ui) |
1000V |
| Rated Impulse Withstand Voltage (Uimp) |
12kV |
| Rated Short-time Withstand Current (Icw, 1s) |
50kA |
| Rated Short-Circuit Making Capacity (Icm, 690V) |
110kA |
| Mounting |
Base mounting |
| Operating Mode |
Front operated |
| Degree of Protection |
Front IP00 (handle IP65) |
| Terminal Type |
Lug terminals, 50 mm width |
| Mechanical Durability |
6000 operations |
| Standard |
IEC 60947-3 |
| Weight |
15.4 kg |
Applications
- Main isolation switching for low voltage distribution boards in commercial and industrial buildings
- Load isolation ahead of motor control centres and switchgear panels
- Safe manual disconnection points for maintenance in FM and facilities operations
- Panel builder installations requiring high fault-level short-circuit withstand ratings
FAQ
-
Is this an MCB or an isolator?
It's an isolator (switch-disconnector), not an MCB. It has no overload or short-circuit protection — it only provides a manual on/off disconnect, and should be paired with separate MCBs or RCCBs for circuit protection.
-
What does 3-pole mean for this isolator?
3-pole means it switches all three phases on a three-phase supply.
-
Where should this isolator be installed?
Typically as the main incoming switch or a local isolation point ahead of the MCBs/RCCBs in a distribution board, so the whole board (or a section of it) can be isolated for maintenance without needing to trip individual breakers.
-
Can I install this myself?
No. This is trade-only distribution board equipment and must be installed and connected by a licensed electrician in accordance with local wiring regulations.
-
Can this isolator be used to switch a live circuit under load?
Isolators rated for on-load switching can do this within their utilisation category, but check the specific AC rating in the Technical Specifications table — an isolator is not a protective device and should not substitute for a circuit breaker.