ABB Miniature Circuit Breaker 10A 3 Pole TYPE C SH203-C10
Protect 3‑phase installations with reliable overload and short‑circuit protection. This ABB 3‑pole MCB (SH203-C10) is part of the System pro M compact S200 family, delivering current‑limiting performance with thermal and magnetic trips, compliant with IEC, UL and CSA standards for domestic and light commercial boards in the UAE.
Key Features
- 3‑pole protection for 3‑phase circuits
- Type C magnetic trip curve for manageable fault currents
- Thermal (overload) and magnetic (short‑circuit) tripping
- Current‑limiting protection for faster fault clearance
- System pro M compact S200 series
- Bottom‑fixing auxiliary contact saves space
- Through‑hole mounting for quick panel installation
- IEC, UL, CSA compliant
Technical specifications
| Attribute |
Value |
| Brand |
ABB |
| Current rating |
10 A |
| Voltage |
400 V AC |
| Circuit Breaker Type |
Standard |
| Poles |
3 |
| Type |
Type C |
| Trip Mechanisms |
Thermal (overload) and Magnetic (short‑circuit) |
| Trip Curve |
Type C |
| Mounting Type |
Through‑Hole Mount |
| Series |
System pro M compact S200 |
| Standards |
IEC, UL, CSA |
| Auxiliary Contact |
Bottom fixing |
| Datasheet |
Download PDF |
Applications
- Residential distribution boards and consumer units
- Three‑phase lighting and small commercial circuits
- Motor control circuits up to 10 A per phase
- Renewables and building automation panels
FAQ
-
What's the difference between an MCB and an RCCB/RCD?
An MCB (miniature circuit breaker) protects wiring and connected equipment against overload and short-circuit current. An RCCB/RCD protects against earth leakage by monitoring current imbalance. The two are complementary and are normally installed together in a distribution board.
-
What does the Type C tripping curve mean?
Type C trips at 5–10x rated current, giving enough headroom for motors, transformers, and ballast/LED-driver inrush without nuisance tripping.
-
What does the 6kA breaking capacity mean?
6kA is the maximum fault current this MCB can safely interrupt without damage. It should be equal to or higher than the prospective fault current at its installation point in the board.
-
How many poles do I need?
A 3-pole (3P) breaker switches all three phases on a three-phase circuit without a switched neutral.
-
Is this MCB compatible with other ABB DIN-rail distribution boards?
Yes — it's a standard DIN-rail (EN 60715) mounted breaker and clips directly into ABB's modular consumer units and distribution boards alongside other ABB DIN-rail devices.
-
Can I install this myself?
No. This is a distribution board component and must be installed and connected by a licensed electrician in accordance with UAE wiring regulations — it is not a DIY consumer product.