ABB FA2N 1600 3-Pole Withdrawable Air Circuit Breaker
The FA2N 1600 3p WMP is the moving part (breaking unit) for the ABB Formula Air FA2N 1600 withdrawable air circuit breaker, fitted with 4 auxiliary contacts indicating open-closed position of the circuit breaker. Rated at 1600A with a 690V AC operational voltage, it is designed for main distribution switchboards and transformer or generator protection applications in commercial and industrial UAE facilities where high current withdrawable breakers are required.
Key Features
- 1600A rated 3-pole withdrawable moving part for the Formula Air FA2N air circuit breaker range
- Fitted with 4 auxiliary contacts providing open-closed position indication of the circuit breaker
- Rated ultimate breaking capacity (Icu) of 65kA at 400-440V AC, suitable for demanding fault level protection
- Withdrawable design enabling safe isolation and maintenance without full switchboard shutdown
- Genuine ABB quality
Technical Specifications
| Specification |
Details |
| Brand |
ABB |
| Model |
FA2N 1600 3p WMP |
| Poles |
3P |
| Rated Current (In) |
1600A |
| Rated Uninterrupted Current (Iu) |
1600A |
| Rated Operational Voltage |
690V AC |
| Rated Insulation Voltage (Ui) |
1000V AC |
| Rated Impulse Withstand Voltage (Uimp) |
12 kV |
| Rated Ultimate Breaking Capacity (Icu) |
65kA (400-440V AC) / 50kA (500-690V AC) |
| Rated Service Breaking Capacity (Ics) |
100% of Icu |
| Terminal Connection Type |
Withdrawable Circuit-Breaker |
| Auxiliary Contacts |
4 (open-closed position indication) |
| Standards |
IEC 60947-2 |
| Net Weight |
49 kg |
Applications
- Main incomer and transformer protection in large commercial and industrial switchboards
- Generator protection in backup power distribution systems across the UAE
- High current withdrawable breaker applications requiring maintenance without full shutdown
- Main distribution board protection in data centres, hotels, and large facilities
FAQ
-
What's the difference between an MCB and an MCCB?
An MCB (miniature circuit breaker) is typically rated up to 100A with a fixed, non-adjustable trip and lower breaking capacity, used for final circuits. An MCCB (moulded case circuit breaker) is built for higher currents and fault levels, and is used for main incomers, sub-mains, and feeder protection where an MCB's rating or breaking capacity would be insufficient.
-
When do I need an MCCB instead of an MCB?
Use an MCCB where the prospective fault current or load current exceeds what an MCB is rated to handle safely — typically at the main incomer or major sub-main level of a commercial or industrial distribution board.
-
Does this MCCB have an adjustable trip setting?
Check the specific trip unit type in the Technical Specifications table above — thermal-magnetic MCCBs may have a fixed or adjustable trip range depending on the model; an electronic trip unit typically offers configurable protection curves.
-
Can I install this myself?
No. MCCBs are installed in distribution boards and panels by a licensed electrician, in line with UAE wiring regulations.