ABB BMFW440/AC300 Residual Current Circuit Breaker AC Type, 4P, 40A, 300mA

SKU: 1SYF604062R3400
Regular price AED 265.00 inc. VAT
In stock
Usually ships within 24 hours
Ready to work out of the box!

All items are delivered with essential accessories and easy-to-follow instructions. Unbox and start your projects with confidence!

Free shipping
100% secure payments
Industry leading quality

Ask an expert!

ABB BMFW440/AC300 4-Pole 40A 300mA RCCB

The BMFW440/AC300 is a 4-pole 40A residual current circuit breaker (RCCB) with a 300mA AC-type sensitivity from ABB's Formula DIN Rail range. It protects people and installations against earth fault currents and is manufactured to IEC standards, making it suitable for three-phase distribution boards across UAE residential, commercial, and light industrial installations.

Key Features

  • 4-pole configuration for three-phase and neutral circuit protection against earth leakage faults
  • 300mA AC-type sensitivity suitable for general protection against fault currents in standard distribution circuits
  • Rated operational voltage of 230/400V with a 4kV rated impulse withstand voltage for reliable insulation performance
  • IP20 degree of protection with an operating temperature range of -25°C to +55°C, suited to UAE ambient conditions
  • Genuine ABB Formula Din Rail quality — rated for 10,000 electrical and mechanical operating cycles

Technical Specifications

Specification Details
Brand ABB
Model BMFW440/AC300
Type RCCB (ELCB)
Poles 4
Rated Current (In) 40A
Sensitivity 300mA
Input Voltage Type AC
Rated Voltage (Ur) 230/400V
Rated Impulse Withstand Voltage (Uimp) 4kV
Rated Frequency 50Hz
Degree of Protection IP20
Mounting DIN Rail
Connecting Capacity Flexible 35mm² / Solid 25mm²
Electrical & Mechanical Endurance 10,000 cycles
Ambient Operating Temperature -25°C to +55°C

Applications

  • Earth fault protection for three-phase distribution boards in villas and commercial buildings
  • Main incomer protection for sub-distribution boards in FM-managed facilities
  • Fault current protection for HVAC and pump motor circuits in commercial installations
  • General earth leakage protection in retail, warehouse, and light industrial panels across the UAE

FAQ

  • What's the difference between an MCB and an RCCB/RCD?
    An MCB protects circuits and wiring against overload and short-circuit current. An RCCB like this one protects against earth leakage by monitoring current imbalance and disconnecting the circuit — the two are complementary and are normally installed together in a distribution board.
  • What does the 300mA sensitivity rating mean?
    300mA RCCBs are sized for fire and equipment protection on larger circuits and sub-mains, not personal shock protection — that requires a 30mA device. A 300mA unit is a common choice as a main incomer or sub-distribution protection device upstream of 30mA final-circuit RCDs.
  • How many poles do I need?
    A 4-pole (4P) RCCB switches all three phases plus neutral together. Use 4P for three-phase supplies or distribution boards where the neutral must also be isolated; 2-pole devices are used for single-phase circuits.
  • Can this be used alongside MCBs in the same board?
    Yes. This RCCB is typically installed upstream of the MCBs it protects, on the same DIN rail, so a leakage fault trips the RCCB while overloads/short circuits are still cleared by the individual MCBs.
  • Can I install this myself?
    No. RCCBs are wired into a live distribution board and must be installed by a licensed electrician in line with UAE wiring regulations.

Order by 12PM to get delivered next working day! We use 24 hours service with carriers in most cases so that you can get your order delivered on the next day.