{"product_id":"abb-dse201-m-c20-ac30-1p-n-20a-30ma-rcbo","title":"ABB DSE201 M 1P+N RCBO 20A 30mA","description":"\u003ch2\u003eABB DSE201 M 1P+N RCBO 20A 30mA\u003c\/h2\u003e\n\u003cp\u003eThe DSE201 M C20 AC30 is a 1P+N electronic residual current circuit breaker with overcurrent protection (RCBO) in a compact one-module width, combining overload and short-circuit protection with high-sensitivity residual current protection in a single device. With a 30mA Type AC sensitivity, it provides additional protection against direct contacts as well as protection against indirect contacts, making it well suited to end-user single-phase circuits in UAE residential and commercial distribution boards where personnel safety is a priority.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCombined overcurrent and residual current protection in a single 1-module-wide device, saving distribution board space\u003c\/li\u003e\n  \u003cli\u003e20A Type C overcurrent protection paired with 30mA Type AC residual current sensitivity for personnel protection\u003c\/li\u003e\n  \u003cli\u003eAdditional protection against direct contacts as well as protection against indirect contacts\u003c\/li\u003e\n  \u003cli\u003eUnswitched neutral with flying lead connections for neutral and functional earth, simplifying installation\u003c\/li\u003e\n  \u003cli\u003eGenuine ABB quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSE201 M C20 AC30\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd\u003eType C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Residual Current\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResidual Current Type\u003c\/td\u003e\n\u003ctd\u003eType AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Ultimate Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd\u003e15 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Short-Circuit Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e230\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eTerminals IP20 \/ Housing IP40\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePersonnel protection circuits requiring 30mA sensitivity in residential and commercial installations\u003c\/li\u003e\n  \u003cli\u003eBathroom, kitchen, and outdoor socket circuit protection in UAE villas and apartments\u003c\/li\u003e\n  \u003cli\u003eCombined overcurrent and earth leakage protection where direct contact safety is required\u003c\/li\u003e\n  \u003cli\u003eRetrofit upgrade from separate MCB and RCCB to a single combined device in distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Buy From Deluxe Electricals?\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGenuine ABB product — manufacturer quality guaranteed\u003c\/li\u003e\n  \u003cli\u003eStock held in UAE for fast local delivery\u003c\/li\u003e\n  \u003cli\u003eCompetitive trade pricing for bulk and project orders\u003c\/li\u003e\n  \u003cli\u003eExpert technical support from our electrical specialists\u003c\/li\u003e\n  \u003cli\u003eTrusted supplier to contractors, FM companies, and retailers across the UAE\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNeed bulk quantity for your project?\u003c\/strong\u003e Contact us at \u003ca href=\"mailto:sales@deluxeelectricals.me\"\u003esales@deluxeelectricals.me\u003c\/a\u003e for special pricing and fast delivery across the UAE.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44346899726435,"sku":"1SDA067398R1","price":145.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/6570\/1475\/files\/9PAA00000399303_400x400_8f89d56a-9cb1-4717-afe1-b774ea3ec4fe.png?v=1783695078","url":"https:\/\/www.deluxeelectricals.me\/ar\/products\/abb-dse201-m-c20-ac30-1p-n-20a-30ma-rcbo","provider":"Deluxe Electricals","version":"1.0","type":"link"}